Superheated Steam Table — 250 bar (25 MPa)

Specific volume, internal energy, enthalpy, entropy, density and isobaric specific heat of superheated steam at 250 bar (25 MPa), computed from IAPWS-IF97 — the same formulation the SimuPipe solver uses. Rows run from 400 °C to 800 °C in 20 °C steps.

Above the critical pressure
250 bar is above the critical pressure of 22.064 MPa (220.64 bar), so there is no saturation line and no boiling point: water passes continuously from liquid-like to vapour-like as it is heated. The rows below are single-phase supercritical states, still region 2 of IAPWS-IF97, and there is no "Sat." row to quote.
Superheated steam properties at 250 bar (25 MPa) from IAPWS-IF97
T (°C)v (m³/kg)ρ (kg/m³)u (kJ/kg)h (kJ/kg)s (kJ/kg·K)cp (kJ/kg·K)
4006.0053e-3166.51902428.52578.65.139913.0392
4207.5793e-3131.93762580.02769.45.41967.4062
4408.6975e-3114.97582679.62897.15.60135.6026
4609.6166e-3103.98722758.82999.25.74264.6938
4800.01041895.98362826.63087.15.86094.1377
5000.01114289.75032887.43165.95.96423.7661
5200.01181084.67682943.23238.56.05693.5044
5400.01243580.41702995.73306.66.14163.3126
5600.01302876.75763045.63371.36.22033.1679
5800.01359573.55853093.63433.56.29413.0560
6000.01414070.72293140.23493.76.36382.9679
6200.01466768.18113185.63552.36.43022.8976
6400.01517965.88163230.23609.76.49372.8410
6600.01567863.78493274.13666.06.55482.7949
6800.01616561.86053317.43721.56.61362.7574
7000.01664360.08413360.33776.46.67062.7267
7200.01711358.43613402.83830.66.72582.7016
7400.01757556.90063445.13884.56.77942.6812
7600.01803055.46433487.23937.96.83172.6647
7800.01847954.11643529.13991.16.88262.6517
8000.01892252.84743570.94044.06.93242.6415
Reading this table

u is not tabulated independently. Specific internal energy follows from the enthalpy and specific volume as u = h − p·v, with p in MPa and v in m³/kg (1 MPa·m³/kg = 1000 kJ/kg). At 250 bar (25 MPa) that pressure term is worth 473.1 kJ/kg at 800 °C, so u and h are far apart at high pressure and nearly equal at low pressure — a common source of error when the wrong column is read.

The first row is saturated vapour on subcritical pages; this page has none, because there is no saturation line above the critical pressure.

Values are IAPWS-IF97, not interpolated. Every row is evaluated directly from the industrial formulation at that exact temperature, so there is no interpolation error between rows. If you need a temperature between the 20 °C steps, the calculator computes it exactly.

Superheated tables at other pressures